Difference Between Neutral and Grounding Conductors - NY Engineers (2024)

Neutral and grounding wires are often confused outside of the electrical trade since both conductors have zero voltage allowing mistakes to easily be made without the implementation of wiring color codes. Actually, if you connect the grounding wire as a neutral by mistake, most devices will operate correctly. However, such a connection is against code, since each conductor has a different function in an electrical installation.

The National Electrical Code (NFPA 70 NEC) establishes insulation colors for the neutral and grounding wires. Standard colors simplify an electrical installation, while making it safer.

  • Neutral wire colors: White or grey
  • Grounding wire colors: Green, green-yellow or bare

These insulation colors are only allowed for neutral and ground conductors, and using them for any of the live voltage phases is against the code. Electricians work with the assumption that wiring of these colors is at zero voltage, and using white or green insulation for a live conductor would be a deadly trap (and against code in the first place).

Get a professional electrical design for your next building project.

Difference Between Neutral and Grounding Conductors - NY Engineers (1)

Role of the Neutral Conductor in Electric Circuits

Difference Between Neutral and Grounding Conductors - NY Engineers (2)

To visualize how the neutral conductor works, consider that electric power is delivered as current across a voltage difference. Voltage is carried by the live conductor, but a neutral conductor is also necessary for two important functions:

  • Serving as a zero voltage reference point.
  • Completing the circuit, providing a return path for the current supplied by the live conductor.

If only the live conductor is connected to an electrical device, it will not activate because current cannot circulate, regardless of the voltage applied. This is similar to how a hydroelectric turbine requires an outlet to produce motion: if the turbine discharge is blocked, water cannot flow and the turbine cannot rotate.

When an installation uses three-phase power, there may be cases in which the neutral conductor is not required.

  • A three-phase system with a line voltage of 120V provides 208V between phases, and you can connect a 208V load between two phases without using a neutral wire. Both live conductors carry voltage, but current can flow because they have different voltages.
  • Three-phase loads like electric motors are often designed to run with three live conductors and no neutral conductor. The same principle applies here: current can flow between live conductors at different voltages.

Even if some loads don’t use the neutral conductor in a three-phase installation, it is needed for single-phase loads that only use one of the line voltages. In theory, when identical loads are connected to the three phases, their currents cancel out and the neutral conductor carries zero current. However, this is unfeasible in real-life installations, and the neutral conductor carries the current imbalance between the three phases.

Role of the Grounding Conductor in Electric Circuits

Difference Between Neutral and Grounding Conductors - NY Engineers (3)

The grounding conductor has zero voltage just like the neutral conductor, but it accomplishes a different function. As implied by its name, this conductor provides a grounded connection for all appliances and equipment.

  • Under normal conditions, all current returns through the neutral conductor, and the grounding conductor has no current.
  • When a line fault occurs, the grounding conductor provides a return path for the fault current. Electrical protection devices can detect this condition, and they immediately disconnect the circuit from the power supply.

Without a grounding connection, appliances and equipment become energized if a live wire touches them accidentally. The fault is not disconnected, since protection devices can only respond when there is a fault current in a grounding wire. In this case, anyone who touches the energized surface will suffer an electric shock.

Since a ground fault can affect any circuit, the grounding conductor is required even when there is no neutral wire. For example, if a motor uses three live conductors and no neutral, grounding is still required because any of the live wires can cause a fault.

Sizing Neutral and Grounding Conductors Correctly

Live conductors are sized for the current they are expected to carry, and the same applies for neutral conductors in single-phase circuits (they carry the same current as the live wire). However, different rules apply for three-phase circuits: a common practice is using the same wire size as the phase conductors, but some applications require a larger wire size for the neutral conductor.

  • Grounding conductors for branch circuits are sized based on the capacity of the overcurrent protection device, using tables provided in the NEC.
  • On the other hand, grounding conductors for the main service entrance are sized based on the capacity of service conductors. The NEC provides tables for both cases.

By working with qualified electrical engineers from the start of the project, you can rest assured that all components are specified according to the NEC and local codes. This not only provides safety, but also a quick project approval with local authorities. Electrical engineers can also suggest energy efficiency measures to save on power bills.

Why Hire Electrical Engineers To Handle Development Projects

When you’re developing a real-estate or office project, you need to get everything ready for what your future tenants will need. From an HVAC system to an optimal energy plan, you’re better off hiring professionals than going with cheaper solutions. Our teams of electrical engineers are very familiar with the entire construction process and will always come up with the best solution for your building. Electrical engineering design is no simple task.

Hiring Electrical Engineers Will Ensure the Success of Your Project

Electrical engineering is an essential part of every residential development project. You want your building to follow all of the legal guidelines, and our electrical engineers will help you do just that. Networks are complex and must be able to sustain all of your equipment and facilities. A team of professional contractors will design and install a network that’s tailored to your building’s specific needs, ensuring that your activities can go on without any hitches.

Electrical Engineering Design that Saves You Money

Your building’s electrical circuits are the cornerstone which supports your activity. Whether you need to support specialized equipment, office equipment, heating, ventilation, water pumps, we can help you save money in the long haul. With the constant surges registered on the energy markets, having professionals to provide a design that minimizes costs is definitely the way to go.

New York Engineers has you covered. We have professionals trained in every field, so we have the knowledge that’s required in designing feasible, low-maintenance electrical engineering projects.

What Makes Us Different From Other Firms

We know that your time and money are valuable. That’s why we provide you with accurate estimates and a very quick design proposal. You’ll be getting an estimate in less than 24 hours after requesting for one. We do our best to stay within the original estimate, and we make sure to finish our projects as fast as possible. Some people work smart, some people work hard. We do both.

Something as trivial as a 24-hour delay can mean huge shifts in your budget. That is why we guarantee that our design process is 50% faster than anything else you can find in the industry.

We Keep You in the Loop

Our professionals will keep you constantly informed in regards to the project’s development, possible delays, anything that you’d want to know about. Any questions that you have will be answered by someone who is up to speed and working within the development team.

Take the First Step and Reach Out for a Free Estimate

If you’re on the ropes, then our free estimate should put your worries to rest. Our teams of electrical engineers are sure to send you an accurate initial cost and help you understand your future building’s electrical needs. Save money, and work with a team of dedicated professionals who will keep you informed every step of the way.

Difference Between Neutral and Grounding Conductors - NY Engineers (2024)

FAQs

Difference Between Neutral and Grounding Conductors - NY Engineers? ›

Under normal conditions, all current returns through the neutral conductor, and the grounding conductor has no current. When a line fault occurs, the grounding conductor provides a return path for the fault current.

What is the difference between a neutral conductor and a grounded conductor? ›

According to the terminology in the CEC and NEC, the “grounding” conductor is for the safety ground, i.e., the green or bare or green with a yellow stripe wire. The word “neutral” is reserved for the white when you have a circuit with more than one “hot” wire.

What is the difference between the neutral and ground wire? ›

The neutral wire provides the return path for AC current, while the ground wire serves as a safety measure. Solar power systems need to be properly grounded and bonded to your home's electrical system to comply with safety standards and prevent electrical hazards.

What is the difference between neutral and equipment grounding? ›

Neutral is the return path provided from load to supply. The current will flow from source to load and then returns to source through closed path formed by neutral. Whereas earthing is used for protection of humans surrounding an electric equipment.

How do you tell the difference between neutral and ground on a multimeter? ›

If the ground wire is determined, turn the multimeter to the highest voltage range, take the ground wire as the common point, and measure the voltage of the ground wire and the other two wires respectively. The one with no voltage is the neutral wire, and the one with voltage is the live wire.

What happens if you use a ground wire as a neutral? ›

Actually, if you connect the grounding wire as a neutral by mistake, most devices will operate correctly. However, such a connection is against code, since each conductor has a different function in an electrical installation.

What is the potential difference between neutral and ground? ›

In an AC circuit, the earth and the neutral point must be at the same potential, ideally, the potential difference between the two will be zero.

What happens if earth and neutral wires touch? ›

Nothing if load is balanced on the circuit. If load is unbalanced a spark will occur and trip the circuit breaker if rated properly. If the wire is not loaded nothing will happen but it is a dangerous situation to leave neutral and ground wires connected.

How much voltage is between neutral and ground? ›

The important point here is that inside the breaker panel, both NEUTRAL and GROUND are connected to the same point. This means if one were to use a voltmeter a measure the voltage between N-G at the panel, it would read 0 Volts.

What happens if neutral is not grounded? ›

if neutral isnt connected you will still have 110v to ground but not to neutral. no, you will not get 55 volts if you seperate the ground and the neutral at the main. you bond the neutral to the ground in the main panel to make sure they are both at the same voltage which will be zero.

What is the difference between grounded and ungrounded neutral? ›

“Ungrounded Systems” require insulation faults at two different points and a large enough voltage difference between those two points before current will flow through the ground. As we will discuss later, “Grounded Systems” only require one fault to result in electrical current flow through the ground.

What is the purpose of a neutral wire? ›

The neutral wire carries the electricity back to the power source. It completes the circuit by directing the current to a ground or busbar, normally located at the electrical panel. Once the power is “used” at the demand point, it carries it back to the panel.

Does a grounded conductor carry current? ›

The NEC even refers to a Grounded Conductor as a Current-Carrying Conductor. On the other hand, an Equipment Grounding Conductor (bare or green) only carries current during a short-to-ground condition, when electrical current is briefly introduced onto normally non-current-carrying metal parts.

Is there a difference between neutral and ground? ›

They are at the same potential but with one very important distinction. The neutral wire carries the full load current as the hot wire while the ground carries… absolutely zero current. The neutral is designed to be the return for the hot wire to complete the circuit.

Why do I have 120 volts between neutral and ground? ›

If neutral-ground voltage is about 120 V and hot-ground is a few volts or less, then hot and neutral have been reversed. Under load conditions, there should be some neutral-ground voltage - 2 V or a little bit less is pretty typical.

What happens if live and neutral are reversed? ›

It can also cause fire if the reverse polarity goes undetected and damages wires or components that lead to sparks, which in turn causes a fire. And the worst is still yet to come, if you keep your outlet reversed you are increasing the potentials of electrical shocks.

What is the meaning of neutral conductor? ›

Neutral is a circuit conductor that normally completes the circuit back to the source. NEC states that the neutral and ground wires should be connected at the neutral point of the transformer or generator, or otherwise some "system neutral point" but not anywhere else.

Can I use ground as neutral for a smart switch? ›

A: DO NOT use ground as neutral! Ground wires are typically not shielded, and it'll be a huge electrical hazard. These switches will sip 1-2W which means there'll be current passed to the neutral wires. If you don't know what you are doing, DON'T DO IT!

What is the difference between a grounded conductor and an ungrounded conductor? ›

The grounding conductor should never have current, except under fault conditions. What is the difference between a grounded and ungrounded electrical cord? Grounded electrical is are connected to ground(earth) and ungrounded electrical cord is not.

What does it mean when a neutral is grounded? ›

grounded neutral in Electrical Engineering

(graʊndɪd nutrəl) noun. (Electrical engineering: Electrical power) Grounded neutral is the situation in which the neutral wire of an electrical supply system is connected to ground.

Top Articles
Latest Posts
Article information

Author: Stevie Stamm

Last Updated:

Views: 6335

Rating: 5 / 5 (80 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Stevie Stamm

Birthday: 1996-06-22

Address: Apt. 419 4200 Sipes Estate, East Delmerview, WY 05617

Phone: +342332224300

Job: Future Advertising Analyst

Hobby: Leather crafting, Puzzles, Leather crafting, scrapbook, Urban exploration, Cabaret, Skateboarding

Introduction: My name is Stevie Stamm, I am a colorful, sparkling, splendid, vast, open, hilarious, tender person who loves writing and wants to share my knowledge and understanding with you.